Fire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray Nozzle

Product Details
Customization: Available
Sprinkler Installation: Pendent
Sprinkler Head Type: Closed
Still deciding? Get samples of US$ 0.6/Piece
Request Sample
Gold Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
  • Fire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray Nozzle
  • Fire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray Nozzle
  • Fire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray Nozzle
  • Fire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray Nozzle
  • Fire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray Nozzle
Find Similar Products

Basic Info.

Model NO.
ZST
Alarm Valve Type
Wet Alarm Valve
Automatically Opened and Closed Repeatedly
Can′t Automatically Opened and Closed
Open Fire Sprinkler System Type
Water Spray System
Wet Alarm Valve Structure
Seat Type
Alarm Valve Diameter
150mm
Nozzle Flow Coefficient
80
Response Temperature
57deg;68deg, 79deg, 93deg, 141deg
Nominal Diameter
DN15, DN20
Bulb Color
Orange, Red, Yellow, Green, Orchid, Purple
Working Pressure
1.2MPa
Transport Package
Crate or Carton
Trademark
GAN
Origin
Shenzhen, China
Production Capacity
1000 Pieces/Month

Product Description

Fire Sprinkler Head With Glass Bulb Sprinkler 15~150L/Min Spray Nozzle

 

Product description:

There are several types of fire sprinklers: pendant type, upright type, ordinary type, side wall type and concealed type sprinkler

This water mist nozzle consists of frame, apex and deflector. It is to protect areas with combustibles that water will be atomized by the deflector and ejected when it flows into the nozzle once a fire happens. The nozzle will keep spraying water mist to prevent fire from spreading during the fire disaster.

Product Features:

1. Water is the only needed extinguishing agent.

2. Foam solution can also be added to put out liquid caused fire.

3. It can be used combine with other extinguishing system such as the powder system.

Technical Parameters:

Model Rated Working Pressure(MPa) Flow(L/min) Flow Coefficient(K) Atomize Angle
ZSTWC8 0.35 15 8

60°

90°

120°

150°

180°

ZSTWC11.8 22 11.8
ZSTWC14.9 28 14.9
ZSTWC16 30 16
ZSTWC21 40 21
ZSTWC27 50 27
ZSTWC34 63.6 34
ZSTWC42 80 42
ZSTWC50 93.5 50
ZSTWC57 106.6 57
ZSTWC80 150 80
ZSTWC86 160 86
ZSTWC107 200 107
ZSTWC115 215 115
ZSTWC160 300 160

 

Classification:

1. The drooping sprinkler is the most widely used sprinkler. It is installed drooping on the water supply branch pipe. The shape of the sprinkler is parabolic, spraying 80-100% of the total water to the ground. Mainly used in places that do not need decoration, such as workshops, warehouses, parking garages, kitchens, etc.

2. The upright sprinkler is installed upright on the water supply branch pipe. The sprinkling shape is parabolic, spraying 80-100% of the total water volume downwards, and part of it is sprayed to the ceiling. It is suitable for installation in places where there are many moving objects and are prone to collisions. In places such as warehouses, it can also be concealed on the roof of the room ceiling mezzanine to protect the ceiling boron with more flammable materials.

3. Ordinary sprinklers can be installed directly, or they can be installed downwardly on the sprinkler pipe network, spraying 40%-60% of the total water volume down, and the larger part is sprayed to the ceiling. It is suitable for restaurants, shops, warehouses, underground garages and other places.

4. Side wall sprinklers are installed against the wall, which is suitable for installation in places where space is difficult to pipe. They are mainly used in light-dangerous parts of buildings such as offices, halls, lounges, and corridor rooms.
 

Fire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray NozzleFire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray NozzleFire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray NozzleFire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray NozzleFire Sprinkler Head with Glass Bulb Sprinkler 15~150L/Min Spray Nozzle

 

FAQ

 

1. What is the minimum order quantity for your product?
The minimum order quantity is one set/set.Foam liquid is generally 1000 liters

 

2. Do you have your own factory manufacturer?
Yes, we have been a manufacturer for more than 20 years. Our main products are foam fire extinguishing equipment, bladder storage tank foam system, balanced pressure distribution system, etc. We can provide a one-stop service including fire protection products.

 

3. What are your payment terms?
We accept wire transfer, letter of credit, Western Union, Paypal, etc.

 

4. How long is the delivery time?
Usually about 15 days after payment, if you have custom or other requirements for delivery time, you need to communicate again.

 

5. Can OEM be accepted?
Yes, we provide customized designs for customers.

 

You are welcome to contact us, we provide in-depth customized services to better solve your product needs!

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier