Fire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder Tank

Product Details
Customization: Available
Working Pressure: 0.5~1.2MPa
Flow Range: 4,8L/S
Gold Member Since 2015

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (27)
  • Fire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder Tank
  • Fire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder Tank
  • Fire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder Tank
  • Fire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder Tank
  • Fire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder Tank
  • Fire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder Tank
Find Similar Products

Basic Info.

Model NO.
PHYM
Model
Py50-Py500
Tank Capacity
500-10000L
Material
Carbon Steel or Stainless Steel
Product Name
Mobile Foam Unit
Mixing Ratio
3% or 6%
Flow Rate
240L/M~21600L/M
Customized
Available
Transport Package
Pallet or Woodden Case
Trademark
GAN
Origin
Guangong, China
HS Code
8424100000
Production Capacity
100 Set/Sets Per Month

Product Description

INTRODUCTION
The Vertical Foam Bladder Tank is the main unit of the foam extinguishing system. The foam tank and the low/medium expansion foam generator construct the low/medium foam spraying system. It can also construct the high expansion total flooding extinguishing system with high expansion foam generator.


PRINCIPLE
The device consists of pressure tank, bladder, proportioner, pressure gauge, valves and pipeline. A pump is needed to supply pressurized water. When pressurized water flow though proportioner, a small part of water (3%-6%) flow into tank from branch pipe to press the bladder to swap out equal foam concentrate and then mix with another part of water (97%-93%) to form foam solution in proportioner and provide to foam generator.


PARAMETERS

Proportioner
Model No.
PHY4 PHY8 PHY16 PHY24 PHY32 PHY40 PHY64 PHY72
Diameter (DN) 50 65 80 100 100 150 150 150
Mixing Ratio 3% or 6%
Rated Working Pressure (MPa) 1.2
Working Pressure Range (MPa) 0.3~1.2
Rated Flow (L/S) 4 8 16 24 32 40 64 72
Flow Rang (L/S) 1~4 2~8 3~16 4~24 8~32 12~40 15~64 17~72
Pressure Drop (MPa) ≤0.2


INSTALLATION
Device should be installed at places with shelter to avoid sun and rain. Ambient temperature should be within 40°C and leave enough space for operation. Device should be installed at concrete floor and fastened with anchor nuts.
Do the hydraulic test after installing. Open the tank vent valve first then fill water into bladder from concentrate draining pipe. Then close tank vent valve when bladder is full of water. Pressurize the system and keeping for 10 minutes when pressure gets test pressure, tank should have no leakage. Close water inlet valve and open water drainage valve and concentrate drainage valve to drain water away in tank and bladder. (We will do this test when products leave the factory)

CAPACITY LITERS D
mm
L
mm
L1
mm
B
mm
B1
mm
H
mm
H1
mm
WEIGHT
(KG)
500 800 810 600 1000 1150 1700 1200 280
1000 1000 1010 800 1200 1350 2100 1200 350
1500 1200 1210 1000 1400 1550 2100 1200 450
2000 1400 1410 1200 1600 1750 2050 1200 550
3000 1400 1410 1200 1600 1750 2450 1200 800
4000 1600 1600 1400 1800 1950 2800 1200 1050
5000 1700 1680 1500 1900 2050 3000 1200 1200
6000 1800 1760 1600 2000 2150 3300 1200 1400
8000 1900 1820 1700 2100 2250 3800 1200 1600
9000 2000 1920 1800 2200 2350 3900 1200 1900
10000 2200 2120 2000 2400 2550 4300 1200 2200

 

Characteristics of foam tank

1 The foam tank has stable mixing ratio and high reliability, and can provide high-quality foam mixed liquid.

2. The foam tank has the smallest pressure drop, the sprayed foam extinguishing agent has large energy and strong penetrating ability. Can quickly put out the fire.

3. Save foam liquid and reduce fire extinguishing costs. Because the capsule of the foam tank separates the foam liquid from the water, the foam liquid is not used up at one time and can be used next time, and the mixing accuracy is stable and reliable.

4. It has a wide range of applications, no matter high, medium or low expansion foam fire extinguishing agent can be used. The foam ratio mixing device of the automatic foam fire extinguishing system can be used with foam nozzles or sprinklers.

 

Size and weight are just for reference, real products can be different.

Fire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder TankFire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder TankFire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder TankFire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder TankFire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder TankFire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder Tank

Company Information

  With a history of more than 20 years, Shenzhen Winan Industrial Development Co. Ltd. is a professional manufacturer and exporter who are focusing on designing, developing and manufacturing all kinds of Fire fighting equipment. The company now has a large area of industrial workshops of more than 10000 square meters, located in Shenzhen, China, with convenient transportation access.

 Fire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder Tank

  All of our products comply with international quality standards and are greatly appreciated in a variety of different markets throughout the world. Our well-equipped facilities and excellent quality control throughout all stages of production enables us to guarantee total customer satisfaction. As a result of our high quality products and outstanding customer service, we have gained a global sales network around the world.

Certification

Fire Extinguishing Foam Suppression System 240L~21600L Vertical Foam Bladder Tank

FAQ:

1. Do you offer free sample for your clients?

     Yes, we can offer you free sample.

2. What's the MOQ of your products?

     MOQ is ONE pcs/set.

3. Are you manufacturer with your own factory?

     Yes, we are the manufacturer for more than 20 years

4. What's your payment terms?

     We accept T/T, L/C, Western Union, Paypal,etc.

5. How long is the delivery time?

     Usually around 15 days after payment.

6. Can you accept OEM?

    Yes, we do customized design for our clients.

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier